Challenge
Decades of inspection history sit in paper files nobody can search.
Agnotic approach
History is scanned, extracted and verified, and the page behind each reading is kept.

For integrity and inspection managers whose RBI method lives in spreadsheets and whose history lives in paper files. Agnotic Technologies builds risk-based inspection software that applies your method to every vessel, piping circuit and tank, digitizes your inspection history and works in plants where mobile devices are not allowed inside.
Trusted by global innovators
























Your method, applied the same way
Risk-based inspection software follows your own API 580 and 581 method when your integrity engineers define the rules and the software applies them the same way to every pressure vessel, piping circuit and storage tank. Agnotic Technologies builds it around the damage mechanisms, probability and consequence categories, risk targets and planning rules your team already uses, so the risk results stay yours and every score traces back to its inputs. The software stores readings and findings per equipment item, recalculates risk when new data arrives and proposes the next inspection, which an authorized inspector or integrity engineer reviews and approves.
Your engineers own the method and validate the software's results against worked examples before go-live; we do not present the calculations as certified by API. The RBI module can stand alone or sit inside wider asset integrity management software.
Scan each report and drawing once, then extract the data that drives risk: thickness readings by location, inspection dates, findings, repairs and replacements. An AI model reads typed and handwritten reports into draft records, and an inspector checks each draft against the scan before it enters the history.
Start with the equipment whose risk depends most on its history, such as piping circuits with active corrosion, rather than scanning the archive in date order. Readings that cannot be read, or that conflict with later data, are listed for an engineer instead of being guessed.
Each record keeps its scanned page attached, so anyone can open the original report behind a corrosion rate. The extraction runs on the same AI document processing methods we use for other scanned records.
API 510 and API 570 inspection data entry works best when each reading is entered against a named equipment item and a fixed thickness measurement location, not typed into a free-form report. The software then calculates corrosion rates and remaining life the way your procedure defines them, and flags readings that do not fit the trend.
Then the software is built so nothing has to be carried into the unit. Inspectors work from worksheets printed by the system, each with a barcode for the equipment item and its measurement locations, and enter or scan the results at a terminal outside the unit.
The record shows when a reading was taken and when it was entered, so the gap between the two is visible to reviewers and auditors.
An RBI software company builds the equipment register, the inspection history, the risk calculation and the inspection planning that connects them, all configured to your method. As a services company, Agnotic Technologies builds these for your plant rather than selling a fixed product your method has to fit.
The work also covers the less visible parts: data cleaning, migration of past inspections, links to your CMMS for work orders and to your process historian for operating data, and the reports your inspectors and regulators read. Live sensor data from compressors, pumps and other rotating equipment belongs in oil and gas asset monitoring.
Buried and transmission pipelines follow different integrity rules and are covered by pipeline inspection software; this page is about fixed equipment in the plant.
Risk-based inspection software is only as current as the data it receives from the systems around it.
Equipment master data in, inspection and repair work orders out, such as with SAP PM or Maximo.
Operating temperatures and pressures that decide which damage mechanisms apply.
Drawings, data sheets and past reports linked to each equipment item.
Process or equipment changes that should send an item back for risk review.
AI drafts records from scanned reports; an inspector checks each one before it counts.
Readings exported from ultrasonic gauges and imported after the round.
Architecture
The components we build, what each one does and the technology we typically use. The exact stack follows your systems and hosting rules.
| Component | Purpose | Typical tech |
|---|---|---|
| Equipment register | Vessels, piping circuits, tanks and relief devices with design data and hierarchy | Relational database, imports from your CMMS and line lists |
| Inspection history | Thickness readings, findings, repairs and scans per equipment item | Document storage, OCR and AI extraction with inspector review |
| Damage mechanism review | Which mechanisms apply to each item, as set by your corrosion and materials engineers | Rule tables configured with your engineers |
| Risk engine | Probability and consequence of failure by your method, recalculated when data changes | Versioned calculation service, tested against your worked examples |
| Inspection planning | Proposes the next inspection date, method and coverage for approval | Planning rules, approval workflow and electronic sign-off |
| Integration layer | Sends work orders out and brings operating data and gauge files in | REST APIs, CMMS connectors and file imports |
Hosting can be on premises or in your cloud account. Inspection data stays in storage you control.
Failure points
Problems we see in inspection programs that run on paper and spreadsheets, and what the software changes.
Challenge
Decades of inspection history sit in paper files nobody can search.
Agnotic approach
History is scanned, extracted and verified, and the page behind each reading is kept.
Challenge
Risk results live in a spreadsheet only one engineer understands.
Agnotic approach
The method is configured once, versioned and applied the same way to every item.
Challenge
Thickness readings are retyped from field sheets with errors.
Agnotic approach
Readings are entered against fixed locations, with checks for values that break the trend.
Challenge
Plans are not revisited when process conditions change.
Agnotic approach
A change in operating data or a new finding sends the item back for risk review.
Challenge
Overdue inspections are found during an audit.
Agnotic approach
Due and overdue inspections are listed per unit, with the plan's approver named.
Challenge
Findings never become work orders.
Agnotic approach
Repairs go to your CMMS and close back into the inspection history.
The size of a risk-based inspection software build follows the number of equipment items and units, how much paper history needs digitizing, how detailed your RBI method is, from qualitative to quantitative, and the systems it connects to. We do not publish prices; the first release is scoped on the scoping call.
Most plants start with one process unit and its history, then extend unit by unit. Reliability and performance analytics across the wider fleet sit in asset performance management software.
Rollout
Five steps from the scoping call to risk-based plans your engineers approve.
We review your RBI method, equipment count, data sources and the state of your paper records.
Your integrity engineers set damage mechanisms, risk matrix, targets and planning rules with us.
Paper history for one process unit is scanned, extracted and verified by your inspectors.
Risk results are compared with your engineers' own calculations for the same equipment before anyone relies on them.
More units, tanks and integrations follow once the first unit's results are accepted.
Who it is for
Plants where fixed equipment integrity is a safety and regulatory question.
Pressure vessel, piping and tank programs under process safety rules.
Covered processes under OSHA process safety management or the EPA Risk Management Program.
Fixed equipment inspection beside live asset monitoring.
Storage tank inspection history and planning in one place.
Contract inspectors who need data entry that fits each client's method.
US process safety rules that set what mechanical integrity inspections cover and record, each linked to the regulation text on eCFR.
OSHA's process safety management standard, 29 CFR 1910.119(j)(1), applies its mechanical integrity rules to pressure vessels and storage tanks, piping systems, relief and vent systems, emergency shutdown systems, controls and pumps.
Source: 29 CFR 1910.119(j) (eCFR)29 CFR 1910.119(j)(4) requires inspection and testing procedures to follow recognized and generally accepted good engineering practices, at a frequency consistent with manufacturers' recommendations and good engineering practices, and more often if prior operating experience shows it is needed.
Source: 29 CFR 1910.119(j)(4) (eCFR)Under 29 CFR 1910.119(j)(4)(iv), each inspection and test on process equipment must be documented with its date, the name of the person who performed it, the equipment's serial number or other identifier, a description of the inspection or test and its results.
Source: 29 CFR 1910.119(j)(4)(iv) (eCFR)29 CFR 1910.119(j)(5) requires equipment deficiencies outside acceptable limits to be corrected before further use, or in a safe and timely manner when the necessary means are taken to assure safe operation.
Source: 29 CFR 1910.119(j)(5) (eCFR)EPA's Risk Management Program rule, 40 CFR 68.73, sets the same mechanical integrity duties for Program 3 processes, including inspections that follow recognized and generally accepted good engineering practices and documentation of each inspection and test.
Source: 40 CFR 68.73 (eCFR)Standards