Overhead view of a foam-lined case holding a micrometer, digital caliper, dial indicator, torque wrench and gauge blocks with calibration stickers, beside a rugged tablet

    Calibration Management

    Calibration management software for gauges, instruments and audits

    Calibration due dates live in a spreadsheet, certificates in a binder, and nobody can say which parts were measured with the gauge that just failed. Agnotic Technologies builds calibration management software that tracks every gauge, schedules each calibration and traces the impact when one is out of tolerance.

    Gauge registerDue date trackingOut-of-tolerance impactCertificates on file

    Trusted by global innovators

    Benchmark
    Chibasco
    Fundency
    Lantimer
    Lera
    One Minute
    Pento Pix
    TAP
    Xtrium
    Benchmark
    Chibasco
    Fundency
    Lantimer
    Lera
    One Minute
    Pento Pix
    TAP
    Xtrium
    Benchmark
    Chibasco
    Fundency
    Lantimer
    Lera
    One Minute
    Pento Pix
    TAP
    Xtrium
    Benchmark
    Chibasco
    Fundency
    Lantimer
    Lera
    One Minute
    Pento Pix
    TAP
    Xtrium

    What is calibration management software?

    Calibration management software keeps a register of every gauge and instrument a plant uses to accept product, schedules each calibration from its interval, stores the certificate and results, and blocks or flags a gauge that is overdue or out of tolerance. Agnotic Technologies builds it around your own gauge list, intervals and labs, whether calibrations are done in house or by an outside lab. When a gauge fails, the software lists the parts and lots it measured since its last good calibration, so quality can decide what to recheck. Auditors get the full history of any instrument in one place instead of a binder and a spreadsheet.

    Audit readiness

    How do we track gauge calibration due dates before an ISO 9001 audit?

    Put every gauge in one register with an interval and a next due date, and let the software send the due list to the owner and the calibration lab before the date, not after it. A gauge that passes its due date changes status and cannot be picked on an inspection record until it is recalibrated.

    Before an audit, the quality lead runs the report an auditor usually asks for: every gauge in use, its last calibration, its certificate and its next due date, with any overdue or missing record flagged so it can be fixed first.

    Gauge record

    What does each gauge record hold?

    One record per instrument, so its whole history answers one search.

    Identity

    • Gauge ID with a barcode or QR label
    • Type, make, model and serial number
    • Range and resolution
    • Location and owner

    Calibration plan

    • Interval in days or in uses
    • Procedure or work instruction
    • Acceptance limits
    • In-house or outside lab

    Calibration events

    • As-found and as-left results
    • Pass or fail against the limits
    • Certificate file and lab name
    • Reference standards used and their traceability

    Usage

    • Inspection records that used the gauge
    • Parts and lots it measured
    • Check-out and return to the crib

    Out-of-tolerance flow

    What happens when a gauge fails calibration?

    The impact review the software runs, so a failed gauge never leaves an open question about parts already shipped.

    1. Record the as-found result

      The lab or technician enters an as-found value outside the limits, and the gauge moves to out-of-tolerance status.

    2. Find what it measured

      The software lists inspection records, parts and lots measured with the gauge since its last passing calibration.

    3. Assess the impact

      Quality compares the gauge error with the tolerances on those parts to see whether bad parts could have been accepted.

    4. Recheck, hold or release

      Lots at risk are rechecked, held or released, each with a recorded reason and approver.

    5. Open a CAPA when needed

      Repeated failures or damage open a corrective action linked to the gauge record.

    6. Return to service

      The adjusted and recalibrated gauge returns with its new certificate and next due date.

    Gauge status

    Which status can a gauge have?

    The status rules the inspection screens follow. Each gauge is in exactly one status.

    CodeNameTypical use
    ACTIVEIn calibrationCan be picked on inspection records
    DUEDue soonStill usable; the owner and the lab are reminded
    OVERDUEPast its due dateBlocked from new inspection records until recalibrated
    OUTOut for calibrationOff the floor, with the expected return date tracked
    OOTOut of toleranceBlocked, and an impact review is opened
    RETIREDRetired or lostKept in history and never selectable again

    Audit evidence

    What auditors usually ask to see

    Answered from the calibration records, not assembled by hand the week before.

    • The list of measuring equipment in use and where it is
    • The last calibration and certificate for a sampled gauge
    • Traceability of the reference standards the lab used
    • What was done when a gauge was found out of tolerance
    • How overdue gauges are kept out of use
    • Who calibrated, checked and released each instrument

    What do we build into calibration management software?

    Modules for the gauge crib, the lab and the quality office.

    Gauge register

    Every instrument with its labels, limits, owner, location and status.

    Calibration scheduling

    Due lists by interval or usage, with reminders to owners and outside labs.

    Results and certificates

    As-found and as-left values checked against limits, with certificates attached.

    Use blocking

    Overdue and out-of-tolerance gauges cannot be picked on inspection records.

    Certificate reading

    AI reads outside lab certificates into result fields for a technician to confirm.

    Impact review

    Reverse traceability from a failed gauge to the parts and lots it measured.

    Check-out and crib

    Barcode check-out and return, so the software knows who has each gauge.

    Integrations

    Inspection systems, CMMS and QMS, so status and usage stay in step.

    Failure points

    Why do spreadsheets miss calibration dates?

    Where calibration tracking breaks before it moves into software, and what changes.

    Challenge

    The due date is a cell nobody looks at until the audit.

    Agnotic approach

    Due lists go to owners and labs automatically, and late gauges change status.

    Challenge

    An overdue gauge is still in the drawer and still used.

    Agnotic approach

    Overdue gauges are blocked on inspection records, so use stops at the point of measurement.

    Challenge

    Certificates are in a binder or an email folder.

    Agnotic approach

    Each certificate is attached to the calibration event it belongs to.

    Challenge

    Nobody knows what a failed gauge measured.

    Agnotic approach

    Inspection records store the gauge ID, so the impact list is one query.

    Challenge

    Personal gauges and spares are never registered.

    Agnotic approach

    Check-out by barcode puts every gauge in the register before it can be used.

    Facts and sources

    Which rules require calibration records?

    FDA calibration rules and the NIST traceability policy, each linked to its primary source.

    • For drug makers, 21 CFR 211.160(b)(4) requires instruments, apparatus, gauges and recording devices to be calibrated at suitable intervals under a written program with schedules, accuracy and precision limits and remedial action, and instruments that do not meet specifications must not be used.

      Source: 21 CFR 211.160(b)(4) (eCFR)
    • 21 CFR 211.68(a) requires automatic, mechanical and electronic equipment used in drug manufacturing to be routinely calibrated, inspected or checked under a written program, and written records of those calibration checks and inspections must be kept.

      Source: 21 CFR 211.68(a) (eCFR)
    • Under FDA's good laboratory practice rule, 21 CFR 58.63(c), written records must be kept of all inspection, maintenance, testing, calibrating or standardizing operations, and each record must contain the date of the operation.

      Source: 21 CFR 58.63(c) (eCFR)
    • NIST adopts the international vocabulary of metrology definition of metrological traceability: a property of a measurement result whereby it can be related to a reference through a documented unbroken chain of calibrations, each contributing to the measurement uncertainty. NIST also states that other organizations are responsible for establishing the traceability of their own results.

      Source: NIST Policy on Metrological Traceability

    Standards

    Standards behind a calibration program

    ISO 9001ISO/IEC 17025ISO 1348521 CFR 211.16021 CFR 58.63NIST traceability

    Scope

    What decides the size of a calibration build?

    We do not publish prices. These are the drivers we size on the scoping call.

    Gauges and sites

    How many instruments, cribs and sites the register covers.

    In-house and outside labs

    Who calibrates what, and how certificates arrive today.

    Use blocking

    Which inspection systems must check gauge status before a measurement is saved.

    Impact review

    Whether inspection records already store the gauge used, or that needs adding.

    Integrations

    CMMS, QMS and ERP links for repairs, CAPAs and asset data.

    Migration

    Existing spreadsheets and certificate archives to bring across.

    Engagement

    How does a calibration software project run?

    We start from your current gauge list and the next audit on your calendar.

    1.

    Scoping call

    We review your gauge list, intervals, labs and how certificates are filed today.

    Scope
    2.

    First release for one site

    A fixed-scope first release: register, scheduling, certificates and use blocking for one site.

    Build
    3.

    Impact review and more sites

    Reverse traceability, more sites and the integrations, with support after launch.

    Scale

    Who it is for

    Teams that rely on calibration records

    Teams that accept product on measurements and must show those measurements were right.

    Machining and fabrication shops

    Calipers, micrometers, height gauges and thread gauges shared across shifts.

    Drug and supplement makers

    Lab instruments and production equipment calibrated under a written program.

    Medical device makers

    Measuring equipment records that support a quality system built on ISO 13485.

    Food plants

    Thermometers, scales and metal detectors checked on a schedule.

    Frequently Asked Questions

    Yes, where inspections are recorded in software. Overdue and out-of-tolerance gauges cannot be picked on an inspection record, and a scan of a blocked gauge shows why it is blocked.