Challenge
Accuracy drops on images from a different scanner vendor or protocol.
Agnotic approach
Datasets are sampled across vendors, models and protocols, and results are reported per subgroup.
A model that segments or measures images in a notebook is not yet software a radiologist can use. Agnotic Technologies builds medical image analysis software that returns results as DICOM objects the reading workflow can store, trained on de-identified, well-labelled data and scoped to the claim you intend to make.
Trusted by global innovators
























Quantitative imaging
Medical image analysis software measures, segments, detects or quantifies findings in CT, MRI, X-ray, ultrasound and other medical images, and returns the results in a form clinical systems can store and display. Agnotic Technologies builds this image analysis software for imaging startups, device makers and hospital research teams.
The algorithm is only part of the product. The rest is getting images in, writing results back as standard DICOM objects, building the labelled data the algorithm learns from, and documenting what it was tested on.
Storage, viewers and image transport are separate builds, covered on our medical imaging PACS and DICOM integration pages. This page is about the analysis layer and the evidence behind it.
Output objects
Results written as standard DICOM objects can be stored next to the source study and shown in existing viewers, instead of living in a separate app.
| Code | Name | Typical use |
|---|---|---|
| DICOM SEG | Segmentation | Labelled regions such as an organ, tumour or vessel, stored as binary, fractional or label map frames that reference the source images |
| SR TID 1500 | Measurement | Lengths, areas, volumes and derived values in a Measurement Report, each tied to the region and image it was taken from |
| SR TID 1500 | Detection | Findings with their location and tracking ID, so a viewer can list them and jump to each one |
| Parametric Map | Quantification | Per-pixel real-world values, such as perfusion or diffusion parameters, stored as an image the viewer can overlay |
| Secondary Capture | Fallback display | A rendered image for viewers that cannot display SEG or SR, never the only copy of the result |
Claim to classification
The claim you make decides the regulation, and the regulation decides what the validation study must show. This table is a planning aid for the conversation with your regulatory advisors, not a regulatory determination.
| What the software claims | 21 CFR section | Output it writes back | What the validation must show |
|---|---|---|---|
| Displays, processes and measures images for a trained practitioner to interpret | 892.2050, medical image management and processing system | Segmentations and semi-automated measurements (SEG, SR) | Measurement accuracy against reference values and correct handling of DICOM inputs |
| Marks parts of an image that may show an abnormality during the read | 892.2070, medical image analyzer (CADe) | Marks or regions with locations (SR, SEG) | Standalone performance and whether readers perform better with the device, by relevant subgroup |
| Flags time-sensitive studies and notifies clinicians, without marking the image | 892.2080, computer aided triage and notification | A notification and worklist priority, not image marks | Effective triage, such as faster time to review for prioritized studies |
| Characterizes a lesion as suspicious for cancer | 892.2060, computer-assisted diagnostic software | A characterization for each lesion (SR) | Improved reader performance and standalone performance in the intended population |
| Detects, locates and characterizes findings such as fractures | 892.2090, computer-assisted detection and diagnosis | Findings with locations and characteristics (SR, SEG) | Standalone testing including localization accuracy, plus assisted-read performance |
A research tool that makes no clinical claim may sit outside these sections, but its output must then be labelled for research use and kept out of clinical reports.
Ground truth
The labels an algorithm learns from and is tested against decide what its results are worth.
What counts as the structure or finding, on which series, at which window settings, and what to do with unclear cases.
Images are de-identified inside the hospital using a DICOM PS3.15 Annex E profile, and pixels are checked for burned-in text before anything leaves.
Each case is labelled by more than one qualified reader working independently, in an annotation tool that writes DICOM SEG or SR.
Agreement between readers is measured per case, and cases below the agreed threshold go to adjudication.
A senior reader resolves disagreements, and the decision and its reason are recorded with the case.
Training, tuning and test sets are split by patient and site, versioned, and the test set is locked before final testing.
Failure points
Problems we design against from the first sprint.
Challenge
Accuracy drops on images from a different scanner vendor or protocol.
Agnotic approach
Datasets are sampled across vendors, models and protocols, and results are reported per subgroup.
Challenge
The same patient appears in training and test data.
Agnotic approach
Splits are made by patient and by site, checked automatically before every training run.
Challenge
Patient details survive in private tags or burned into pixels.
Agnotic approach
De-identification covers private attributes and runs a pixel check, with failed studies held back.
Challenge
Segmentations do not line up with the source images in the viewer.
Agnotic approach
Every SEG object keeps the Frame of Reference and source image references, tested in the viewers your users run.
Challenge
Nobody can say which model version produced a result.
Agnotic approach
Each output records the algorithm name and version, and every release has its own test report.
Challenge
Results arrive after the radiologist has finished the read.
Agnotic approach
Processing time is measured on realistic study sizes, and the result routing is agreed with the reading team.
Research or clinical
Many image analysis products start as research tools. Planning for the clinical version from the start saves rework later.
The analysis service receives studies from the PACS or a router, processes them and sends the SEG, SR or parametric map back to be stored with the original study. The radiologist opens the results in the viewer they already use.
Transport, worklists and DICOMweb are covered on our DICOM and PACS integration page. Worklist triage and radiologist notification are covered on our diagnostic imaging AI page.
For pathology slides, the same principles apply with whole slide images, which are covered on our digital pathology page.
What sizes this build
We do not publish prices or use a calculator. These are the inputs we size an image analysis build from on the scoping call.
Each modality, body region and protocol adds data to collect, label and test.
How many studies per day the service must process and how large they are, which sets compute and storage needs.
Measurement, segmentation, detection or quantification, and whether results need a reader in the loop.
How many cases need labels, how many readers per case and how specialized the readers must be.
Whether the build is research use only or needs a validation study shaped by a clinical claim.
Which archives, routers and viewers must receive and display the results.
Who it is for
Teams that have the clinical idea or the algorithm and need the software, data and evidence around it.
Founders with an algorithm or a clinical question who need a product that runs on real hospital data.
Companies adding analysis features to scanners, ultrasound systems or imaging software.
Radiology and research teams turning an internal model into a tool other sites can run.
Specialties that measure anatomy on images every day, such as alignment, joint space or bone density.
Teams that need consistent, repeatable measurements across sites and timepoints.
From the claim you want to make to software running on real studies.
We agree the clinical question, the intended claim, the modalities and the data you can access.
ScopeWe set up de-identification, the labelling protocol and the dataset splits with your clinical team.
DataWe build the analysis service with DICOM inputs and outputs, tested on a locked dataset, with test records kept as we go.
BuildWe add sites, modalities or a clinical validation study, and support the software in production.
ScaleStandards
The DICOM parts and FDA regulations the outputs and evidence are built to.
The FDA classifications and DICOM parts that shape the outputs and evidence, each linked to its primary source.
21 CFR 892.2050 classifies medical image management and processing systems as Class II, and names image segmentation, multimodality image registration and semi-automated measurements among their advanced processing functions.
Source: 21 CFR 892.2050 (eCFR)21 CFR 892.2070 describes a medical image analyzer (CADe) as a device that marks or highlights parts of a radiology image that may reveal abnormalities, and states it is not intended for triage or to recommend a diagnosis.
Source: 21 CFR 892.2070 (eCFR)For radiological computer-assisted detection and diagnosis software, 21 CFR 892.2090 requires standalone performance testing, and a device with localization output must include localization accuracy testing.
Source: 21 CFR 892.2090 (eCFR)The DICOM Segmentation IOD stores a classification of pixels in one or more referenced images, and a segmentation can be binary, fractional or a label map.
Source: DICOM PS3.3, A.51 Segmentation IOD (NEMA)DICOM PS3.15 Annex E defines Attribute Confidentiality Profiles for removing or replacing identifying attributes, and notes that de-identifying the attributes does not by itself de-identify the whole object.
Source: DICOM PS3.15, Annex E Attribute Confidentiality Profiles (NEMA)Health Insurance Portability and Accountability Act
Protect PHI with privacy-first architecture, encrypted storage and transmission, strict access controls, and traceable audit logs.
General Data Protection Regulation
Implement lawful consent flows, data minimization, retention controls, and secure processing for sensitive health data.
Fast Healthcare Interoperability Resources
Enable standardized health data exchange across apps, care teams, and systems through standards-based FHIR APIs.
Health Level Seven International
Support enterprise-grade interoperability with HL7-based integrations for records, events, and clinical messaging workflows.
Health Information Trust Alliance
Align security programs to healthcare-specific control and risk management practices trusted by providers and ecosystem partners.
Health Information Technology for Economic and Clinical Health Act
Design with breach notification readiness, digital record safeguards, and operational controls that support regulated care programs.
FDA Software as a Medical Device
Plan software quality, traceability, and documentation pathways for products that may require SaMD review and submission.
Medical Device Regulation (European Union)
Prepare EU market-ready processes for risk classification, evidence tracking, and lifecycle governance under MDR expectations.
Substance Abuse and Mental Health Services Administration
Apply confidentiality controls and consent-aware sharing models for behavioral and mental health data experiences.