Medical Image Analysis Software

    Medical image analysis software development

    A model that segments or measures images in a notebook is not yet software a radiologist can use. Agnotic Technologies builds medical image analysis software that returns results as DICOM objects the reading workflow can store, trained on de-identified, well-labelled data and scoped to the claim you intend to make.

    DICOM SEG and SRGround truth pipelinesPS3.15 de-identification21 CFR 892 claim mapping

    Trusted by global innovators

    Benchmark
    Chibasco
    Fundency
    Lantimer
    Lauren
    Lera
    One Minute
    Pento Pix
    TAP
    Xtrium
    Healthevolve
    Benchmark
    Chibasco
    Fundency
    Lantimer
    Lauren
    Lera
    One Minute
    Pento Pix
    TAP
    Xtrium
    Healthevolve
    Benchmark
    Chibasco
    Fundency
    Lantimer
    Lauren
    Lera
    One Minute
    Pento Pix
    TAP
    Xtrium
    Healthevolve
    Benchmark
    Chibasco
    Fundency
    Lantimer
    Lauren
    Lera
    One Minute
    Pento Pix
    TAP
    Xtrium
    Healthevolve

    Quantitative imaging

    What is medical image analysis software?

    Medical image analysis software measures, segments, detects or quantifies findings in CT, MRI, X-ray, ultrasound and other medical images, and returns the results in a form clinical systems can store and display. Agnotic Technologies builds this image analysis software for imaging startups, device makers and hospital research teams.

    The algorithm is only part of the product. The rest is getting images in, writing results back as standard DICOM objects, building the labelled data the algorithm learns from, and documenting what it was tested on.

    Storage, viewers and image transport are separate builds, covered on our medical imaging PACS and DICOM integration pages. This page is about the analysis layer and the evidence behind it.

    Output objects

    Which DICOM object does each type of analysis write back?

    Results written as standard DICOM objects can be stored next to the source study and shown in existing viewers, instead of living in a separate app.

    CodeNameTypical use
    DICOM SEGSegmentationLabelled regions such as an organ, tumour or vessel, stored as binary, fractional or label map frames that reference the source images
    SR TID 1500MeasurementLengths, areas, volumes and derived values in a Measurement Report, each tied to the region and image it was taken from
    SR TID 1500DetectionFindings with their location and tracking ID, so a viewer can list them and jump to each one
    Parametric MapQuantificationPer-pixel real-world values, such as perfusion or diffusion parameters, stored as an image the viewer can overlay
    Secondary CaptureFallback displayA rendered image for viewers that cannot display SEG or SR, never the only copy of the result

    Claim to classification

    Which FDA classification fits what your software claims?

    The claim you make decides the regulation, and the regulation decides what the validation study must show. This table is a planning aid for the conversation with your regulatory advisors, not a regulatory determination.

    What the software claims21 CFR sectionOutput it writes backWhat the validation must show
    Displays, processes and measures images for a trained practitioner to interpret892.2050, medical image management and processing systemSegmentations and semi-automated measurements (SEG, SR)Measurement accuracy against reference values and correct handling of DICOM inputs
    Marks parts of an image that may show an abnormality during the read892.2070, medical image analyzer (CADe)Marks or regions with locations (SR, SEG)Standalone performance and whether readers perform better with the device, by relevant subgroup
    Flags time-sensitive studies and notifies clinicians, without marking the image892.2080, computer aided triage and notificationA notification and worklist priority, not image marksEffective triage, such as faster time to review for prioritized studies
    Characterizes a lesion as suspicious for cancer892.2060, computer-assisted diagnostic softwareA characterization for each lesion (SR)Improved reader performance and standalone performance in the intended population
    Detects, locates and characterizes findings such as fractures892.2090, computer-assisted detection and diagnosisFindings with locations and characteristics (SR, SEG)Standalone testing including localization accuracy, plus assisted-read performance

    A research tool that makes no clinical claim may sit outside these sections, but its output must then be labelled for research use and kept out of clinical reports.

    Ground truth

    How do we build the annotation and ground truth pipeline?

    The labels an algorithm learns from and is tested against decide what its results are worth.

    1. Write the labelling protocol

      What counts as the structure or finding, on which series, at which window settings, and what to do with unclear cases.

    2. De-identify before export

      Images are de-identified inside the hospital using a DICOM PS3.15 Annex E profile, and pixels are checked for burned-in text before anything leaves.

    3. Annotate with qualified readers

      Each case is labelled by more than one qualified reader working independently, in an annotation tool that writes DICOM SEG or SR.

    4. Measure reader agreement

      Agreement between readers is measured per case, and cases below the agreed threshold go to adjudication.

    5. Adjudicate

      A senior reader resolves disagreements, and the decision and its reason are recorded with the case.

    6. Freeze and version the datasets

      Training, tuning and test sets are split by patient and site, versioned, and the test set is locked before final testing.

    Failure points

    Why do image analysis models fail after they leave the lab?

    Problems we design against from the first sprint.

    Challenge

    Accuracy drops on images from a different scanner vendor or protocol.

    Agnotic approach

    Datasets are sampled across vendors, models and protocols, and results are reported per subgroup.

    Challenge

    The same patient appears in training and test data.

    Agnotic approach

    Splits are made by patient and by site, checked automatically before every training run.

    Challenge

    Patient details survive in private tags or burned into pixels.

    Agnotic approach

    De-identification covers private attributes and runs a pixel check, with failed studies held back.

    Challenge

    Segmentations do not line up with the source images in the viewer.

    Agnotic approach

    Every SEG object keeps the Frame of Reference and source image references, tested in the viewers your users run.

    Challenge

    Nobody can say which model version produced a result.

    Agnotic approach

    Each output records the algorithm name and version, and every release has its own test report.

    Challenge

    Results arrive after the radiologist has finished the read.

    Agnotic approach

    Processing time is measured on realistic study sizes, and the result routing is agreed with the reading team.

    Research or clinical

    Research use or clinical use: what changes?

    Many image analysis products start as research tools. Planning for the clinical version from the start saves rework later.

    • A research use only build can run on retrospective, de-identified data without a clinical claim, but its output stays out of patient reports
    • A clinical build needs a written intended use, a claim and the matching 21 CFR section agreed with your regulatory advisors
    • Clinical builds need requirements, risk analysis, traceability and test records produced during development, not rebuilt afterwards
    • Datasets used in research can only support a clinical submission if their labelling protocol and provenance were recorded
    • Clinical builds need version control of the model and its training data, so every result can be traced to a release
    • We design the research build so the same pipeline, outputs and records carry over to the clinical one

    How does the result reach the radiologist?

    The analysis service receives studies from the PACS or a router, processes them and sends the SEG, SR or parametric map back to be stored with the original study. The radiologist opens the results in the viewer they already use.

    Transport, worklists and DICOMweb are covered on our DICOM and PACS integration page. Worklist triage and radiologist notification are covered on our diagnostic imaging AI page.

    For pathology slides, the same principles apply with whole slide images, which are covered on our digital pathology page.

    What sizes this build

    What drives the cost of image analysis software?

    We do not publish prices or use a calculator. These are the inputs we size an image analysis build from on the scoping call.

    Modalities and body regions

    Each modality, body region and protocol adds data to collect, label and test.

    Study volume and size

    How many studies per day the service must process and how large they are, which sets compute and storage needs.

    Analysis type

    Measurement, segmentation, detection or quantification, and whether results need a reader in the loop.

    Ground truth effort

    How many cases need labels, how many readers per case and how specialized the readers must be.

    Model validation

    Whether the build is research use only or needs a validation study shaped by a clinical claim.

    PACS and viewer integration

    Which archives, routers and viewers must receive and display the results.

    Who it is for

    Who builds image analysis software with us?

    Teams that have the clinical idea or the algorithm and need the software, data and evidence around it.

    Image analysis software for startups

    Founders with an algorithm or a clinical question who need a product that runs on real hospital data.

    Medical device makers

    Companies adding analysis features to scanners, ultrasound systems or imaging software.

    Hospital research groups

    Radiology and research teams turning an internal model into a tool other sites can run.

    Orthopedic and specialty practices

    Specialties that measure anatomy on images every day, such as alignment, joint space or bone density.

    Clinical trial imaging teams

    Teams that need consistent, repeatable measurements across sites and timepoints.

    Engagement

    How does an image analysis engagement work?

    From the claim you want to make to software running on real studies.

    1.

    Scoping call

    We agree the clinical question, the intended claim, the modalities and the data you can access.

    Scope
    2.

    Data and labelling plan

    We set up de-identification, the labelling protocol and the dataset splits with your clinical team.

    Data
    3.

    Fixed-scope first release

    We build the analysis service with DICOM inputs and outputs, tested on a locked dataset, with test records kept as we go.

    Build
    4.

    Scale and support

    We add sites, modalities or a clinical validation study, and support the software in production.

    Scale

    Standards

    Standards our image analysis software follows

    The DICOM parts and FDA regulations the outputs and evidence are built to.

    DICOM SEGDICOM SRParametric MapPS3.15 Annex E21 CFR 892
    Facts and sources

    Facts behind medical image analysis software

    The FDA classifications and DICOM parts that shape the outputs and evidence, each linked to its primary source.

    • 21 CFR 892.2050 classifies medical image management and processing systems as Class II, and names image segmentation, multimodality image registration and semi-automated measurements among their advanced processing functions.

      Source: 21 CFR 892.2050 (eCFR)
    • 21 CFR 892.2070 describes a medical image analyzer (CADe) as a device that marks or highlights parts of a radiology image that may reveal abnormalities, and states it is not intended for triage or to recommend a diagnosis.

      Source: 21 CFR 892.2070 (eCFR)
    • For radiological computer-assisted detection and diagnosis software, 21 CFR 892.2090 requires standalone performance testing, and a device with localization output must include localization accuracy testing.

      Source: 21 CFR 892.2090 (eCFR)
    • The DICOM Segmentation IOD stores a classification of pixels in one or more referenced images, and a segmentation can be binary, fractional or a label map.

      Source: DICOM PS3.3, A.51 Segmentation IOD (NEMA)
    • DICOM PS3.15 Annex E defines Attribute Confidentiality Profiles for removing or replacing identifying attributes, and notes that de-identifying the attributes does not by itself de-identify the whole object.

      Source: DICOM PS3.15, Annex E Attribute Confidentiality Profiles (NEMA)

    Compliance-First Healthcare App Development Services Backed by Global Standards

    01HIPAA logo

    HIPAA

    Health Insurance Portability and Accountability Act

    Protect PHI with privacy-first architecture, encrypted storage and transmission, strict access controls, and traceable audit logs.

    02GDPR logo

    GDPR

    General Data Protection Regulation

    Implement lawful consent flows, data minimization, retention controls, and secure processing for sensitive health data.

    03FHIR logo

    FHIR

    Fast Healthcare Interoperability Resources

    Enable standardized health data exchange across apps, care teams, and systems through standards-based FHIR APIs.

    04HL7 logo

    HL7

    Health Level Seven International

    Support enterprise-grade interoperability with HL7-based integrations for records, events, and clinical messaging workflows.

    05HITRUST logo

    HITRUST

    Health Information Trust Alliance

    Align security programs to healthcare-specific control and risk management practices trusted by providers and ecosystem partners.

    06HITECH logo

    HITECH

    Health Information Technology for Economic and Clinical Health Act

    Design with breach notification readiness, digital record safeguards, and operational controls that support regulated care programs.

    07SaMD logo

    SaMD

    FDA Software as a Medical Device

    Plan software quality, traceability, and documentation pathways for products that may require SaMD review and submission.

    08MDR (EU) logo

    MDR (EU)

    Medical Device Regulation (European Union)

    Prepare EU market-ready processes for risk classification, evidence tracking, and lifecycle governance under MDR expectations.

    09SAMHSA logo

    SAMHSA

    Substance Abuse and Mental Health Services Administration

    Apply confidentiality controls and consent-aware sharing models for behavioral and mental health data experiences.

    Frequently Asked Questions

    We do not publish a price or use a calculator. Cost follows the modalities, study volume, analysis type, labelling effort, the validation the claim needs and the PACS and viewers to integrate. You get a written proposal after the scoping call.