Infection prevention teams spend much of their day finding cases: reading culture results, checking whether a patient had a central line or a recent surgery, deciding whether an infection meets surveillance definitions, and preparing reports. When that work runs on spreadsheets and manual chart review, a small team can only look at a fraction of what it should.
Epic's Bugsy application is built for this work inside Epic. This guide is for the IT, informatics and infection prevention teams setting it up or improving it. It covers what Epic says Bugsy does, the data surveillance depends on, how the daily workflow should run, how reporting to the CDC's surveillance network fits, how to spot trends early, and what usually goes wrong.
What is Epic Bugsy for infection surveillance?
Improving infection surveillance in Epic?
Agnotic builds Epic integrations and data feeds that support infection prevention surveillance and reporting.
Epic Bugsy is Epic's infectious disease application, used by infection preventionists and other clinical staff for surveillance, trend analysis and reporting to regulators when patients acquire infections during their care. For IT and informatics teams, setting it up well means feeding it the right microbiology, device, procedure and location data, with a workflow the team can sustain.
The aim is to move preventionists from searching for cases to reviewing them. Software that surfaces likely cases with the evidence attached lets a small team cover far more patients than manual chart review allows.
That shift depends on trust. Preventionists will rely on the case list only if it rarely misses a case they would have found by hand, so early validation against manual review is part of the setup, not an optional extra.
Which data does infection surveillance depend on?
Surveillance depends on data from several parts of the record arriving accurately and on time. Missing or late data means missed cases or wasted review.
- Microbiology: Culture results, organisms, susceptibilities and specimen sources, including results from reference labs.
- Devices: Insertion and removal times for central lines, urinary catheters and ventilators, documented by nursing.
- Procedures: Surgical procedures with dates, types and wound classes.
- Locations: Patient movement between units, needed to attribute infections to the right place.
- Vital signs and labs: Fever and other criteria that surveillance definitions use.
- Isolation status: Current precautions and flags for organisms that need them.
Device documentation is often the weakest link. If line insertion and removal times are not charted consistently, device-days and device-associated infection counts will be wrong however good the software is.
How should the daily surveillance workflow run?
A good workflow gives preventionists a prioritized list of possible cases each day, with the evidence needed to decide quickly, and records each decision.
- 1. Case finding: Rules flag positive cultures and other triggers for review.
- 2. Evidence view: Each case shows the relevant culture, device, procedure, location and clinical data together.
- 3. Determination: The preventionist applies surveillance definitions and records the outcome and reasoning.
- 4. Actions: Isolation orders, unit notifications or follow-up tasks created from the case.
- 5. Reporting queue: Confirmed events flow to the reporting process.
Tune the triggers with the infection prevention team over the first months. Triggers that are too broad bury reviewers; triggers that are too narrow miss cases that only manual review would find.
How does reporting to NHSN fit?
Most hospital infection reporting in the United States goes to the CDC's National Healthcare Safety Network, which the CDC describes as the nation's most widely used healthcare-associated infection tracking system. Surveillance software should prepare data in the form NHSN and your reporting programs require, so preventionists are not re-keying events.
- Events: Confirmed infections with the attributes the reporting definitions require.
- Denominators: Patient-days, device-days and procedure counts, calculated from source data.
- Location mapping: Units mapped to the location types the reporting program uses.
- Review before submission: A step for the preventionist to confirm what will be sent.
Denominators deserve as much attention as events. A correct infection count over a wrong device-day count produces a wrong rate, and rates are what leadership and outside programs compare.
How can surveillance spot outbreaks and trends early?
Trend views show clusters of the same organism in the same unit or time period, so the team can investigate before an outbreak spreads.
- Organism clusters: The same organism, or the same resistance pattern, appearing in one unit within a short window.
- Unit rates: Infection and device rates by unit over time, compared with each unit's own history.
- Antibiogram support: Susceptibility patterns summarized for clinicians choosing empiric therapy.
- Alerts for flagged organisms: Notifications when a patient with a flagged organism is admitted or transferred.
Agree in advance what counts as a signal worth investigating, such as a number of matching cases in a unit within a set number of days. A written threshold turns trend charts into action, and it gives the team a defensible record of when and why an investigation started.
How should isolation flags and transfers work?
Isolation flags protect other patients and staff only if they follow the patient. When a patient with a flagged organism is readmitted, transferred or booked for a procedure, the receiving team should know before the patient arrives.
- Persistent flags: Organism flags stay on the record across encounters until infection prevention clears them.
- Admission alerts: The infection prevention team is notified when a flagged patient is admitted or registered.
- Transfer notes: Flags appear on transfer and handoff documents, including to outside facilities.
- Bed placement: Bed management sees isolation needs when assigning rooms.
- Clearance rules: Written criteria for removing a flag, applied the same way every time.
Test the flag path end to end with a dummy patient: admit, transfer, discharge and readmit, and confirm every team saw the flag at each step. Gaps usually appear at the boundaries between departments or facilities, where each system assumes the other one has already passed the flag along.
Who should own infection surveillance data?
Infection prevention owns the surveillance decisions; IT and informatics own the data that feeds them. Writing that split down avoids the common situation where a reporting error sits unresolved because each side assumes the other is fixing it.
- Infection prevention: Surveillance definitions applied, case determinations, outbreak investigation and submission sign-off.
- Laboratory: Organism naming, susceptibility reporting and reference lab result quality.
- Nursing informatics: Device documentation build and compliance.
- IT and integration: Interfaces, location mapping, data quality reports and reporting data preparation.
What should IT teams get right in the build?
IT teams make surveillance reliable by getting interfaces, mappings and documentation build right, and by monitoring them after go-live.
- Microbiology interfaces: Organisms and susceptibilities arriving as coded data, not text, including from reference labs.
- Location mapping: Every unit mapped once and kept current when units open, close or move.
- Device documentation build: Insertion and removal fields that nurses complete consistently.
- Data quality checks: Reports that flag lines with no removal date or cultures with no source.
- Change control: Rule and mapping changes agreed with infection prevention and recorded.
Schedule a monthly data quality review with the infection prevention lead. Most surveillance problems show up first as odd numbers in a denominator or a spike of unreviewed cases, long before anyone notices a wrong rate in a report to leadership.
What are the common infection surveillance mistakes?
The common mistakes are data and workflow problems, not software limits.
- Uncoded microbiology: Text results that rules cannot read.
- Inconsistent device charting: Wrong device-days and missed device-associated cases.
- Stale location maps: New units missing from reporting.
- Broad triggers: Review lists too long to finish each day.
- Manual re-keying: Confirmed events typed into reporting tools by hand.
What are Epic Bugsy best practices?
The practices that hold up keep surveillance data clean, the review list manageable and reporting automated.
- Coded source data: Microbiology, devices and locations as structured data.
- Tuned triggers: Reviewed with infection prevention until the daily list is finishable.
- Evidence in one view: Everything needed for a determination on one screen.
- Automated denominators: Calculated from source data, checked monthly.
- Trend monitoring: Organism and unit trends watched continuously.
How Agnotic can help
Agnotic Technologies supports infection prevention programs on Epic: microbiology and reference lab interfaces with coded results, location and device data mapping, data quality reports, reporting data preparation and trend dashboards. We work with your Epic analysts and infection prevention team, within what your organization has licensed and built.
If preventionists still rely on spreadsheets beside Epic, we start by finding which data gaps force the manual work and closing them first.
Spend less time finding cases
Plan infection surveillance integrations with our engineers, or read more EHR integration articles in the hub.
Related reading on Agnotic