    Medical Device Cybersecurity

    Medical Device Cybersecurity for FDA Submissions

    The device works and the verification is done, then the submission needs a threat model, four architecture views and an SBOM with support dates that nobody has written yet. Agnotic Technologies builds connected device software and produces the cybersecurity documentation FDA expects alongside it, so security evidence is ready when the rest of the file is.

    Trusted by global innovators

    Benchmark
    Chibasco
    Fundency
    Lantimer
    Lauren
    Lera
    One Minute
    Pento Pix
    TAP
    Xtrium
    Healthevolve
    Benchmark
    Chibasco
    Fundency
    Lantimer
    Lauren
    Lera
    One Minute
    Pento Pix
    TAP
    Xtrium
    Healthevolve
    Benchmark
    Chibasco
    Fundency
    Lantimer
    Lauren
    Lera
    One Minute
    Pento Pix
    TAP
    Xtrium
    Healthevolve
    Benchmark
    Chibasco
    Fundency
    Lantimer
    Lauren
    Lera
    One Minute
    Pento Pix
    TAP
    Xtrium
    Healthevolve

    What does the cybersecurity part of an FDA submission contain?

    The cybersecurity part of an FDA premarket submission shows how a device was designed and tested to resist attack: a threat model, a security risk assessment scored on exploitability, security architecture views, an SBOM with support status, testing evidence and customer security labeling. Agnotic Technologies produces this documentation alongside the device software it builds.

    Submission checklist

    Which cybersecurity documents does a premarket submission need?

    This is the checklist we work from on a connected device. Each document traces to the others: threats to risks, risks to controls, controls to tests. Your regulatory team owns the submission; we produce the engineering content.

    DocumentWhat it must showWho produces itWhere FDA's guidance covers it
    Threat modelAssets, entry points, threats and the security objectives for the whole device system, including apps, cloud and update serversAgnotic engineering, reviewed with your quality teamSection V.A.1, Threat Modeling
    Cybersecurity risk assessmentEach threat scored on exploitability, the control chosen and the residual risk, kept apart from the ISO 14971 safety file but linked to itAgnotic engineering with your risk management ownerSection V.A.2, Cybersecurity Risk Assessment
    Security architecture viewsGlobal system, multi-patient harm, updateability and patchability, and security use case views, as diagrams with textAgnotic engineeringSection V.B.2, Security Architecture Views
    SBOM with support statusEvery commercial, open source and off-the-shelf component, with its level of support and end-of-support dateAgnotic engineering, generated from the buildSection V.A.4 and Section VII.C.3
    Unresolved anomalies assessmentKnown defects still open at submission, each checked for security impactAgnotic engineering with your quality teamSection V.A.5
    Cybersecurity testing reportControl testing, fuzzing, attack surface analysis, scanning, binary composition analysis, static and dynamic analysis and a penetration test, with findings and how each was closedAgnotic engineering, with an independent penetration tester where you require oneSection V.C, Cybersecurity Testing
    Labeling and customer documentationSecurity features, recommended network setup, update and end-of-support information, often packaged in an MDS2 formYour regulatory team, with technical content from AgnoticSection VI.A, Labeling Recommendations
    Postmarket vulnerability planHow vulnerabilities will be monitored, disclosed and patched after releaseYour quality team, with the engineering process from AgnoticSection VI.B and Section VII.C.1

    Section numbers refer to FDA's February 2026 guidance. This table is engineering guidance; your regulatory team decides what goes in the submission and how it is presented.

    Is your product a cyber device?

    Section 524B applies to a device that meets all three conditions below. Your regulatory team makes the call; we document the facts it rests on, such as every network path the software can reach.

    Software validated, installed or authorized by you

    The device includes software that you, the sponsor, validated, installed or authorized as a device or in a device. That covers firmware, companion apps and device software functions.

    Able to connect to the internet

    The device has the ability to connect to the internet. FDA reads this broadly, so we map direct and indirect paths, such as a sensor that reaches the cloud through a phone app or a hospital gateway.

    Characteristics that could be vulnerable

    The device contains technological characteristics that could be vulnerable to cybersecurity threats, such as wireless interfaces, update mechanisms, ports and stored credentials.

    What follows if it is

    The submission must include the 524B items, and FDA's guidance describes the documentation it expects. The same guidance also covers devices with cybersecurity risk that are not cyber devices.

    App gallery

    View All

    Lera Health

    Lera Health screenshot 1

    Health evolve

    Security risk

    How is security risk scored apart from safety risk?

    Safety risk asks how likely a hazard is. Security risk asks how easily a weakness could be exploited, because an attacker does not follow a probability curve. We keep the two files separate and linked.

    1.

    Start from the threat model

    Each threat names the asset, the entry point and the attacker's goal, across the device, apps, cloud services and update path.

    2.

    Score exploitability

    Each threat is rated on how easily it could be exploited, using a method agreed with your quality team and recorded with its rationale.

    3.

    Choose and trace controls

    Controls such as authentication, signed updates and encrypted storage are linked to the threats they address and to the tests that prove them.

    4.

    Hand over safety impacts

    Where a security failure could cause patient harm, the item is passed to the ISO 14971 safety file so both teams see the same risk.

    Facts and sources

    Which rules and guidance define device cybersecurity?

    Short facts from the statute and FDA's guidance, each linked to its primary source.

    Which healthcare standards sit alongside device cybersecurity work?

    01HIPAA logo

    HIPAA

    Health Insurance Portability and Accountability Act

    Protect PHI with privacy-first architecture, encrypted storage and transmission, strict access controls, and traceable audit logs.

    02GDPR logo

    GDPR

    General Data Protection Regulation

    Implement lawful consent flows, data minimization, retention controls, and secure processing for sensitive health data.

    03FHIR logo

    FHIR

    Fast Healthcare Interoperability Resources

    Enable standardized health data exchange across apps, care teams, and systems through standards-based FHIR APIs.

    04HL7 logo

    HL7

    Health Level Seven International

    Support enterprise-grade interoperability with HL7-based integrations for records, events, and clinical messaging workflows.

    05HITRUST logo

    HITRUST

    Health Information Trust Alliance

    Align security programs to healthcare-specific control and risk management practices trusted by providers and ecosystem partners.

    06HITECH logo

    HITECH

    Health Information Technology for Economic and Clinical Health Act

    Design with breach notification readiness, digital record safeguards, and operational controls that support regulated care programs.

    07SaMD logo

    SaMD

    FDA Software as a Medical Device

    Plan software quality, traceability, and documentation pathways for products that may require SaMD review and submission.

    08MDR (EU) logo

    MDR (EU)

    Medical Device Regulation (European Union)

    Prepare EU market-ready processes for risk classification, evidence tracking, and lifecycle governance under MDR expectations.

    09SAMHSA logo

    SAMHSA

    Substance Abuse and Mental Health Services Administration

    Apply confidentiality controls and consent-aware sharing models for behavioral and mental health data experiences.

    Medical device cybersecurity FAQs

    It may. FDA reads the ability to connect to the internet broadly: intentionally or unintentionally, through any means, which can include a companion app. Your regulatory team decides, and we document every connection path in the threat model and global system view so the decision rests on facts.

    Build compliantly

    How we deliver on this standard

    Related Services

    Related Integrations

    Related Solutions

    Related Comparisons

    Related Case Studies

    Related Checklists and Tools