A cardiology integration with Epic fails in the lab, not in a slide about APIs. The echo order never reaches the machine, the cath report lives in a PDF the chart cannot open, or the angiogram lands in an archive Radiant also uses and nobody knows which accession is theirs.
Cupid is Epic's cardiovascular information system. An integration has to get orders out, procedure documents back, and images stored where both cardiology and radiology can find them. Epic publishes the interface names for that work. This guide uses those published descriptions and the site's own interface list. It does not invent endpoints Epic has not published.
What problem is an Epic Cupid integration solving?
Connecting cardiology systems to Epic?
Agnotic Technologies builds the order, document, and imaging path around Epic Cupid and the interfaces that site has enabled.
An Epic Cupid integration has to get cardiology orders onto the right device or lab, bring the procedure document back onto the encounter, and decide where images live when Radiant also archives studies. There is no public shortcut API to assume. The site's live interfaces, plus open.epic.com for what Epic has published, are the spec.
Epic's specialty software page describes Cupid as its cardiovascular information system for invasive and non-invasive procedures, and says it is designed to work in combination with a PACS, ECG, and other imaging systems so images and procedural data can sit with the rest of the record. That sentence is the scope. Device connectivity, structured procedure notes, and image links are the work. A mobile app listing is a different project.
Which cardiology steps break when the systems stay separate?
Orders, in-lab documentation, and the signed report break first. Each one can look finished in the lab system and missing on the encounter the referring clinician opens.
- Order: Echo, stress, cath, or device check is placed in Epic and never arrives on the modality worklist or the hemodynamic system.
- Demographics: The lab types a name because the order did not carry the enterprise MRN.
- Procedure log: Contrast, devices, and findings stay in the lab application. The encounter has a blank note.
- Report: A PDF is stored where the lab can see it and the inpatient chart cannot.
- Status: The order stays scheduled after the patient has left the lab, so billing and the referring clinician both wait.
Walk one real case with the lab supervisor before you draw interfaces: place the order, start the case, store the images, sign the report, and open the chart as the referring clinician. Every gap in that walk is a requirement. A requirements list written only from Epic's catalog will miss the step the lab actually does on paper.
Where does Cupid overlap with Radiant?
Cupid and Radiant overlap when a cardiology study is also an imaging study: the order, the result, and the pixels. The mistake is giving both applications the same accession and hoping the archive sorts it out.
Epic's published ancillary catalog says Outgoing Imaging Results and Orders sends orders and results from Radiant, Epic's radiology system, or from Cupid, and that this is the interface that sends those orders and results. Triggers called out on that page include an order reaching scheduled or arrived, later status changes, results, and cancellation of the appointment tied to the order. Incoming imaging results, also published there, bring narrative text and image availability or a link to a PACS back into Epic, tied to a clinical order, over HL7 v2.
- One order owner: Decide whether this exam is a Cupid procedure, a Radiant imaging order, or both, and write that down per procedure code.
- One accession: The worklist, the archive, and the chart must share it. A second accession for the cardiology PDF splits the study.
- Pixels: Store once. Point both the cardiology note and the radiology record at that Study Instance UID if both need to see it.
- Reading work: Agree who signs the report. Two signed reports on one study will disagree in the chart.
Which published interfaces carry orders, results, and device data?
Use the interfaces Epic publishes for cardiology and radiology, then confirm the hospital has them turned on. The names below are from open.epic.com. They are not a private catalog, and they are not a promise that every site has licensed them.
- Outgoing Imaging Results and Orders: Orders and results from Cupid or Radiant to a PACS, a transcription system, or another external system.
- Incoming Ancillary Results for imaging: Narrative or impression, plus image availability or a link, back into Epic for a specific order. Epic describes this as an HL7 v2 exchange over TCP/IP.
- Implantable Device Cardiac: Epic says its cardiology software consumes the IHE Implantable Device Cardiac Observation profile, including an encapsulated PDF or a reference pointer in OBX, and a patient visit option.
- FHIR on open.epic.com: A separate, published API catalog for resources that organization has enabled. Do not assume a Cupid-named operation exists there.
Read the spec link on each open.epic page for the version this hospital runs. Field lists change. Quoting a message structure from memory is how a go-live sends the MRN in the wrong place. If the site's interface analyst says a feed is local and not on that page, document the local name and do not pretend it is a public API.
How do procedure documents get back onto the encounter?
The signed procedure document has to attach to the same order that started the case, as a result the chart can open. A file share full of PDFs is not an integration.
Epic's incoming imaging-results description covers a narrative or impression and a pointer to content stored elsewhere, such as a PACS. The device profile description covers an encapsulated PDF or a reference pointer for implantable cardiac device data. Use those patterns when they match the document you have. For a cath report or an echo worksheet, confirm with the site whether it returns as that result interface, as a scanned document, or as structured data Cupid stores itself because the documentation never left Epic.
- Same order id: The result carries the order identifier Epic sent. A patient-level dump will not file on the encounter.
- Preliminary versus final: Send a status the chart understands. Leaving every document preliminary hides completed cases.
- Addendum: An amended report must replace or link to the original. A second unrelated result looks like a second procedure.
- Author: The signing cardiologist, not the interface account.
What should you confirm on the site before design?
Confirm which of the published interfaces are live, which procedure codes belong to Cupid, and which archive stores the pixels. The public catalog is the menu. The site's bridge list is the order.
- Interface inventory: AE titles or HL7 v2 connections already built for cardiology, and who pages out when they stop.
- Procedure master: Which codes create a Cupid order, which create a Radiant order, and which create both.
- PACS destination: One archive or two. If Radiant and Cupid share a PACS, name the issuer of the accession.
- Devices: Hemodynamics, ECG, and implantable device programmers. Each is a sender. Do not hide them inside 'the PACS project'.
- FHIR: Which resources this organization's open.epic enablement actually includes. Patient and DocumentReference are not a cath-lab feed.
What fails in the lab after go-live?
Go-lives fail when a scheduled status is the only trigger, when a cancelled appointment does not cancel the worklist, and when device PDFs arrive with no visit context.
- Trigger gap: Epic's outgoing description fires when an order is scheduled or arrived. A lab that starts from a walk-in with no status change never gets the order.
- Cancel: The appointment is cancelled in Epic and the modality worklist still shows the patient.
- Device file: An implantable device PDF arrives with a name and no encounter, so the IHE visit option nobody implemented would have mattered.
- Shared archive: Cardiology and radiology delete or move studies under rules the other service did not agree to.
- Time: The lab clock and Epic disagree, so 'arrived' sorts onto yesterday's list.
Reconcile each morning for the first month: Cupid or lab cases with no result in Epic, Epic orders in an active status with no images, and device documents with no encounter. Hand the exception list to the lab supervisor, not only to the interface engine.
How do you keep the integration supportable?
Name an owner for each published interface, store the spec version you built against, and retest when Epic or the lab system is upgraded. Cardiology integrations rot when the only documentation is a person's memory of the cath lab.
Keep a one-page sheet: procedure code, order owner (Cupid, Radiant, or both), outbound interface, image destination, and how the report returns. When a new device is purchased, the sheet says whether it is a new sender or just another C-STORE destination. That is the difference between a project and a ticket.
Treat ECG carts, hemodynamic recorders, and implantable device programmers as separate senders from the PACS. An ECG PDF may return on the result interface, while angiographic frames return as DICOM, and a device interrogation returns on the IHE profile Epic publishes for implantable cardiac devices. One project plan that says 'images' will miss two of those three. Name the sender, the message, and the Epic order it must match. When a study is both a cardiology procedure and a radiology exam, write the accession once and let Radiant and Cupid point at it. Two accessions for one angiogram are how the outside reader and the cath lab open different studies and file two reports.
How Agnotic can help
Agnotic Technologies builds the cardiology integration around the interfaces Epic has published and the ones this hospital has enabled: orders and results between Cupid and external systems, image links and procedure documents back on the order, and the boundary with Radiant when both touch the same study. Agnotic walks a real case with the lab, writes the procedure-code sheet, and leaves the morning reconciliation.
We do not name Epic operations that open.epic.com does not list. If the site needs a local feed, we document it as local.
Plan the Cupid order and image path
Review cardiology orders, documents, and imaging with an engineer, or read more EHR integration guides.
Related reading on Agnotic
Radiant, imaging informatics, DICOM and PACS, and specialty EMR patterns.